Basic Info.
Model NO.
37r5gb/37r5pb/3011gb/3011pb
Application
High-performance Transducer, Three Phase Transducer, General Transducer, High Frequency Converter Transducer
Principle of Work
Vector Control Transducer
Voltage of Power Supply
Low Voltage Variable-Frequency Drive
Link of Transformation
AC-DC-AC Variable-Frequency Drive
Nature of DC Power
Voltage Variable-Frequency Drive
Function
Simple Type, Textile Special, Constant Torque Universal Type
Rated Input Voltage, Frequency
3 Phase 380V-440V, 50/60Hz
Allowed Input Voltage Working Scop
Allowed Input Voltage Working Scop
Rated Output Voltage
0~Rated Input Voltage
Maximum Overload Current
Type G, 150%/Min, 180%/20sec. Type P, 120%/Min, 15
Control Mode
Vf/Current Vector Control
Frequency Controlling Scope
Low Frequency Mode : 0.00-650.00Hz, High Frequency
Set Frequency Resolution
Digital Command: 0.01 Hz Analog Command: 1/1000 Ma
Output Frequency Resolution
0.01 Hz
Frequency Setting Signal
0~10V, 0~20mA
Accelerating Time
0.1-3600 Seconds
Braking Torque
Additional Braking Torque up to 125%
Voltage / Frequency Features
4 Optional Fixed Vf Features, and Random Vf Featu
Ambient Temperature
-10°c~40°c
Storage
Storage-40°c~70°c
Specification
0.75KW-630KW 3 Phase 380V
Product Description
About Alpha
Click Download Product Information» Product Introduction6000E is a high-performance open loop current vector frequency inverter. It adopts 32-Bit DSP, high integration, compact design, perfect protection, high reliability. The controlling software integrates advanced current vector controlling technology and magnetic flux vector controlling technology with strong overload ability which ensures the quick response, stability in low frequency running, high torque output in low frequency. It can meet with a wide application demands with leading technology in global market.» Features Instruction: The design meets CE certification, with some performance exceeding CE standards by more than 50%.- Superior Performance
- Overload capacity of heavy load: 150% 60s, 180% 20s.
- Precision of stable speed:
±0.2% under vector control, ±0.5% under V/F control Speed adjustment: 1:200 under vector control, 1:100 under V/F control.- Dynamic torque repose time less than 20ms under vector control.
- High compatibility:
Rated input voltage: 380V-440V, 380V±20% fluctuation is allowed.- High Temperature increase test:
Stable operation in a 40 degree Celsius environment. 36 protection and alarm functions provide more intelligent protection for devices Specification and Parameter
6000E seriesSeries | Model | Input Voltage | Input | Output | Motor |
current (A) | current (A) | Power (kW) |
ALPHA6000E | 3R75GB | Three-phase 380V | 3.7 | 2.5 | 0.75 |
31R5GB / 31R5PB | 5.4 | 4 | 1.5 |
32R2GB / 32R2PB | 7 | 6 | 2.2 |
3004GB / 3004PB | 10.7 | 9 | 4 |
35R5GB / 35R5PB-N | 15.5 | 13 | 5.5 |
37R5GB / 37R5PB-N | 20.5 | 17 | 7.5 |
3011GB / 3011PB-SJ | 26 | 25 | 11 |
3015GB / 3015PB-SJ | 35 | 32 | 15 |
3018G / 3018P-SJ 3018GB / 3018PB-SJ | 38.5 | 37 | 18.5 |
|
3022G / 3022P-SJ 3022GB / 3022PB-SJ | 46.5 | 45 | 22 |
|
3030G / 3030P-N | 62 | 60 | 30 |
|
3037G/3037P-N 3037GB/3037PB-N | 76 | 75 | 37 |
|
3045G/3045P-N 3045GB/3045PB-N | 92 | 90 | 45 |
|
3055G/3055P-N 3055GB/3055PB-N | 113 | 110 | 55 |
|
3075G/3075P-N 3075GB/3075PB-N | 157 | 152 | 75 |
|
3093G/3093P-N | 180 | 176 | 93 |
|
3110G/3110P-N | 214 | 210 | 110 |
3132G/3132P-N | 256 | 253 | 132 |
3160G/3160P-N | 307 | 304 | 160 |
3185G/3185P-N | 350 | 342 | 185 |
3200G/3200P-N | 385 | 380 | 200 |
3220G/3220P-N | 430 | 426 | 220 |
3250G/3250P-N | 500 | 480 | 250 |
3280G/3280P-N | 548 | 520 | 280 |
3315G/3315P-N | 625 | 600 | 315 |
3355G/3355P-N | 710 | 680 | 355 |
3400G/3400P-N | 760 | 750 | 400 |
3450G/3450P-N | 830 | 820 | 450 |
3500G/3500P-N | 910 | 900 | 500 |
3560G/3560P-N | 970 | 950 | 560 |
3630G/3630P-N | 1070 | 1050 | 630 |
EA200 series Single Phase Input:200~240V,Three Phase Input:380~480V,50/60Hz |
Inverter Model | Adapted motor | Rated output current(A) | Frame |
KW | HP |
EA200-S2R75M | 0.75 | 1 | 4 | E00M |
EA200-S21R5M | 1.5 | 2 | 7 | E00M |
EA200-3R75M | 0.75 | 1 | 2.5 | E00M |
EA200-31R5M | 1.5 | 2 | 3.7 | E00M |
EA200-32R2M | 2.2 | 3 | 5.1 | E00M |
Single Phase Input:200~240V,50/60Hz |
Inverter Model | Adapted motor | Rated output current(A) | Frame |
KW HP |
EA200-S2R75G | 0.75 | 1 | 4 | E00 |
EA200-S21R5G | 1.5 | 2 | 7 | E00 |
EA200-S22R2G | 2.2 | 3 | 10 | E01 |
EA200-S2004G | 4.0 | 5 | 18 | E01 |
Three Phase Input:380~480V,50/60Hz |
Inverter Model | Adapted motor | Rated output Current(A) | Frame |
KW | HP |
EA200-3R75G | 0.75 | 1 | 2.5 | E00 |
EA200-31R5G | 1.5 | 2 | 3.7 | E00 |
EA200-32R2G | 2.2 | 3 | 5.1 | E00 |
EA200-3003G | 3 | 4 | 6.6 | E01 |
EA200-3004G | 4 | 5 | 8.5 | E01 |
EA200-35R5G | 5.5 | 7.5 | 13 | E01 |
EA200-37R5G | 7.5 | 10 | 16 | E02 |
EA200-3011G | 11 | 15 | 25 | E02 |
EA200-3015G | 15 | 20 | 32 | E03 |
EA200-3018G | 18.5 | 25 | 38 | E03 |
EA200-3022G | 22 | 30 | 45 | E04 |
EA200-3030G | 30 | 40 | 60 | E04 |
EA200-3037G | 37 | 50 | 75 | E05 |
EA200-3045G | 45 | 60 | 90 | E05 |
EA200-3055G | 55 | 70 | 110 | E06 |
EA200-3075G | 75 | 100 | 150 | E07 |
A1 series Series | Model | Input Voltage | Power capacity (kVA) | Input current | Output current (A) | Moter power(kW) |
A1 | S2 R4GB | Single-phase 200V~240V 50/60Hz | 1.0 | 5.1 | 2.3 | 0.4 |
S2R75GB | 1.7 | 9.2 | 4.0 | 0.75 |
S21R5GB | 2.8 | 13.1 | 7.0 | 1.5 |
S22R2GB | 4.0 | 23 | 9.6 | 2.2 |
3R75GB | Three-phase 380Vto480V 50/60Hz | 1.6 | 3.7 | 2.1 | 0.75 |
31R5GB | 3.2 | 5.4 | 3.8 | 1.5 |
32R2GB | 4.8 | 7.0 | 5.1 | 2.2 |
3004GB | 6.0 | 10.7 | 9.0 | 4.0 |
Product Description
» Control Loop Terminal Function Type | Terminal No | Name | Terminal Funciton | Specification |
Analog Input | AI1~AI2 | Analog inputs | Receive voltage/current input. Voltage or current are selected by DIP switch SW3 or SW1. Voltage input mode is the default mode. | Input voltage: 0~10V |
Input current: 0~20mA |
Reference ground: GND |
AO/AO1 | Analog output | Be able to output analog voltage/current. Voltage or current are selected by DIP switch SW2. | Output voltage: 0/2~10V |
Output current: 0/4~20mA |
Reference ground: GND |
Analogy Output | AO2 | Analog output | Provide analog voltage/current output, with voltage and current selected by the DIP switch SW5. | Output voltage: 0/2~10V |
Output current: 0/4~20mA |
Reference ground: GND |
Type | Terminal No | Name | Terminal Funciton | Specification |
Commu- nication | 485+ | RS485 interface | 485 differential signal positive terminal | Standard RS-485 communication interface, Not isolated to GND |
485- | 485 differential signal negative terminal |
Multi- Functional Input Terminal | X1~X6 | Multi-function input terminals | It can be defined as a multi-function discrete input terminal through programming. | Optical-isolator input |
Input resistance: R=3.9kΩ |
Input voltage: 0~30V |
Reference ground: COM |
Multi_x001f_Function Output | DO | Open collector output terminal | It can be defined as a multi-function output terminal for pulse signal through programming. It can also be used as an on-off output terminal. | Opto-coupler isolated OC output. |
operating voltage: 0V~26V |
Maximum current: 50mA |
Output frequency: 0~50kHz |
Reference ground: COM |
Electric Replay Output | TA | Relay output | It can be defined as a multi-function relay output terminal through programming. | TA-TB: NC TA-TC: NO Contact capacity: 250VAC/2A (COSΦ=1.0) 250VAC/1A (COSΦ=0.4) 30VDC/1A |
TB |
TC |
RA | Relay output | RA-RC: NO Contact Capacity: 250VAC/2A (COSΦ=1) 250VAC/1A(COSΦ=0.4) 30VDC/1A |
RC |
PLC | Multifunctional input common terminal | When leaving the factory, it is shorted to 24V, and the PLC is internally isolated from 24V. Note: When using PLC, the SW4 jumper on the right side of the control terminal must be disconnected. | X terminal supports NPN and PNP connection methods. |
Power | 10V | +10V power supply | Provide +10V power supply externally (Reference ground: GND) | Maximum output current 20 mA Open circuit voltage can be up to 12V |
24V | +24V power supply | Provide +24V power supply externally (Reference ground: COM) | Maximum output current 100mA |
GND | +10V Reference GND | Reference GND for analog signal and +10V power supply | Inner Isolated from COM COM for +10V, AI1, AI2, and AO1 |
COM | +24V Common GND | Used with other terminals | Isolated from GND |
PE | Shield ground | It is used for grounding of terminal wiring shield layer. Shield layer of analog signal lines, 485 communication lines, and motor cables can be connected to this terminal | It is internally connected to connection terminal PE of main circuit. |
• 50Hz Current curve in stable running• Current wave form of positive and negative reverse» Connecting Diagram
Technical Specification
Subject | Specification |
Rated input voltage, frequency | 3 Phase 380V-440V, 50/60Hz |
Allowed input voltage working scope | 3 Phase 380V: 304V-456V, Voltage imbalance rate less than 3%, frequency less than +-5% |
Rated output voltage | 0~Rated input voltage |
Maximum overload current | Type G, 150%/min, 180%/20Sec. Type P, 120%/min, 150%/sec |
Control mode | VF/Current vector control |
Frequency controlling scope | Low frequency mode : 0.00-650.00Hz, High frequency mode: 0.0~1000Hz |
Frequency accuracy | Digital command: ±0.01 %(-10°C~ +40°C) Analog command: ±0.01 %(15°C~35°C) |
Set frequency resolution | Digital command: 0.01 Hz Analog command: 1/1000 maximum frequency |
Output frequency resolution | 0.01 Hz |
Frequency setting signal | 0~10V, 0~20mA |
Accelerating time | 0.1-3600 Seconds |
Braking torque | Additional braking torque up to 125% |
Voltage / Frequency features | 4 optional fixed VF features , and random VF feature setting with RG VF control |
Protection | Over-voltage, Under-voltage, Current Limit, Over-current, Overload, Electronic thermal relay , Over-heat, over-voltage with stall, short circuit load, touch ground, under-voltage protection, input default phase, output default phase, short circuit of touch ground or phases, motor overload protection, etc. |
Ambient temperature | -10°C~40°C |
Humidity | 5-95% RH |
Storage | Storage-40°C~70°C |
Working condition | Indoor without corrosive gas. |
Installation | Altitude not higher than 1000 Meters without dust, corrosive gas and sunlight direct radiation |
Vibration | Less than 5.9m/s2(0.6g) |
Protection level | lP20 |
» » Spare Parts
• Keyboard
» Size
Address:No.101 Jiayi Industrial Zone, Guixiang Community
Guanlan,Longhua District
Shenzhen, Guangdong, China FAQ
Q&A:Q1: Can I have a sample order?
A1: Yes, we welcome sample order to test and verify the performance and quality. Mixed samples are acceptable too.
Q2: Do you have any MOQ limit?
A2: NO MOQ. Please just send us inquiry, your inquiry will be replied within 24 hours, we will let you know the latest price.Q3: What is the lead time?
A3: Samples take 1-3 days; For quantities less than 200 pieces, the lead time is 14 days; For bulk orders more than 200 pieces, the lead time is about 30 days depends on the actual situation of the production line. The lead time may vary depends on the models.
Q4: How do you ship the goods and how long does it take to arrive?
A4: We usually ship by DHL, UPS, Fedex, TNT, EMS, etc. It takes 3-30 days to arrive depends on the regions and courier. Shipping by air and sea are both available.You may also use your own freight forwarding agent for shipping.
Q5: Do you offer warranty for the products?
A5: Yes, we offer 90 days for exchange, 18 months warranty, and life time technical support and maintenance. Download
Address:
No. 1 Jiayi Industrial Zone, Guixiang Community, Guanlan, Longhua District, Shenzhen, Guangdong, China
Business Type:
Manufacturer/Factory
Business Range:
Electrical & Electronics, Industrial Equipment & Components
Management System Certification:
ISO 9001, QC 080000
Company Introduction:
Shenzhen ALPHA Inverter Co., Ltd. Founded in 2000 is a National Hi-Tech enterprise specializing in R&D, manufacturing, sales and service of electric drive and industrial control equipment. We have more than 300 staffs which more than 70% are professional technical persons in industrial control field.
The headquarters is located in Shenzhen High-tech Industrial Park, which is a modern office of R&D and business affairs, with many R&D laboratories and customer service center. Our production base is located in Futian district, owning many automation production lines and approved of ISO9001: 2008, CE certifications.
We continually import advanced technology around the world, and set up cooperation alliances with many scientific research institutions and colleges. We take tech-centric policy and continuous innovate, and obtain many patents of inventions, appearance design and utility model. Presently, our main products include frequency inverter, converter and servo drive, etc.
ALPHA self-developed ALPHA5000 & 6000 series inverter are with powerful functions, flexible control and excellent performance which can meet all kinds of customers′ demand of machinery and matching and system integration. Besides, we can make customized products according to customer′s special demand in different industries. ALPHA products are widely used in CNC machine, textile, metal, crane, oil, plastic, chemical, municipal engineering, etc.
ALPHA sales and service center are around China including more than 30 branch offices and 50 maintenance centers. ALPHA products are exported to Southeast Asia, India and Pakistan, the Middle East, Africa, Europe and America etc. We have a professional technical service team to provide the omni-directional technical service and support for customers. With the high quality products to win customer′s recognition, meanwhile, we offer high quality services to gain the trust of customers.
ALPHA aims at being the most valuable supplier of automation products and services in the world, focuses in electric drive and industry automation fields, achieves the sustainable return for enterprise and partners.