Application: | High-performance Transducer, Three Phase Transducer, General Transducer, High Frequency Converter Transducer |
---|---|
Output Type: | Triple |
Principle of Work: | Vector Control Transducer |
Switch Mode: | PWM Control |
Main Circuit Type: | Voltage |
Voltage of Power Supply: | Low Voltage Variable-Frequency Drive |
Samples: |
---|
Customization: |
---|
Suppliers with verified business licenses
Series | Model | Input Voltage | Input | Output | Motor |
current (A) | current (A) | Power (kW) | |||
ALPHA6000E | 3R75GB | Three-phase 380V | 3.7 | 2.5 | 0.75 |
31R5GB / 31R5PB | 5.4 | 4 | 1.5 | ||
32R2GB / 32R2PB | 7 | 6 | 2.2 | ||
3004GB / 3004PB | 10.7 | 9 | 4 | ||
35R5GB / 35R5PB-N | 15.5 | 13 | 5.5 | ||
37R5GB / 37R5PB-N | 20.5 | 17 | 7.5 | ||
3011GB / 3011PB-SJ | 26 | 25 | 11 | ||
3015GB / 3015PB-SJ | 35 | 32 | 15 | ||
3018G / 3018P-SJ 3018GB / 3018PB-SJ |
38.5 | 37 | 18.5 | ||
3022G / 3022P-SJ 3022GB / 3022PB-SJ |
46.5 | 45 | 22 | ||
3030G / 3030P-N | 62 | 60 | 30 | ||
3037G/3037P-N 3037GB/3037PB-N |
76 | 75 | 37 | ||
3045G/3045P-N 3045GB/3045PB-N |
92 | 90 | 45 | ||
3055G/3055P-N 3055GB/3055PB-N |
113 | 110 | 55 | ||
3075G/3075P-N 3075GB/3075PB-N |
157 | 152 | 75 | ||
3093G/3093P-N | 180 | 176 | 93 | ||
3110G/3110P-N | 214 | 210 | 110 | ||
3132G/3132P-N | 256 | 253 | 132 | ||
3160G/3160P-N | 307 | 304 | 160 | ||
3185G/3185P-N | 350 | 342 | 185 | ||
3200G/3200P-N | 385 | 380 | 200 | ||
3220G/3220P-N | 430 | 426 | 220 | ||
3250G/3250P-N | 500 | 480 | 250 | ||
3280G/3280P-N | 548 | 520 | 280 | ||
3315G/3315P-N | 625 | 600 | 315 | ||
3355G/3355P-N | 710 | 680 | 355 | ||
3400G/3400P-N | 760 | 750 | 400 | ||
3450G/3450P-N | 830 | 820 | 450 | ||
3500G/3500P-N | 910 | 900 | 500 | ||
3560G/3560P-N | 970 | 950 | 560 | ||
3630G/3630P-N | 1070 | 1050 | 630 |
Single Phase Input:200~240V,Three Phase Input:380~480V,50/60Hz | ||||
Inverter Model |
Adapted motor | Rated output current(A) | Frame |
|
KW | HP | |||
EA200-S2R75M | 0.75 | 1 | 4 | E00M |
EA200-S21R5M | 1.5 | 2 | 7 | E00M |
EA200-3R75M | 0.75 | 1 | 2.5 | E00M |
EA200-31R5M | 1.5 | 2 | 3.7 | E00M |
EA200-32R2M | 2.2 | 3 | 5.1 | E00M |
Single Phase Input:200~240V,50/60Hz | ||||
Inverter Model |
Adapted motor | Rated output current(A) | Frame |
|
KW HP | ||||
EA200-S2R75G | 0.75 | 1 | 4 | E00 |
EA200-S21R5G | 1.5 | 2 | 7 | E00 |
EA200-S22R2G | 2.2 | 3 | 10 | E01 |
EA200-S2004G | 4.0 | 5 | 18 | E01 |
Three Phase Input:380~480V,50/60Hz | ||||
Inverter Model |
Adapted motor | Rated output Current(A) | Frame |
|
KW | HP | |||
EA200-3R75G | 0.75 | 1 | 2.5 | E00 |
EA200-31R5G | 1.5 | 2 | 3.7 | E00 |
EA200-32R2G | 2.2 | 3 | 5.1 | E00 |
EA200-3003G | 3 | 4 | 6.6 | E01 |
EA200-3004G | 4 | 5 | 8.5 | E01 |
EA200-35R5G | 5.5 | 7.5 | 13 | E01 |
EA200-37R5G | 7.5 | 10 | 16 | E02 |
EA200-3011G | 11 | 15 | 25 | E02 |
EA200-3015G | 15 | 20 | 32 | E03 |
EA200-3018G | 18.5 | 25 | 38 | E03 |
EA200-3022G | 22 | 30 | 45 | E04 |
EA200-3030G | 30 | 40 | 60 | E04 |
EA200-3037G | 37 | 50 | 75 | E05 |
EA200-3045G | 45 | 60 | 90 | E05 |
EA200-3055G | 55 | 70 | 110 | E06 |
EA200-3075G | 75 | 100 | 150 | E07 |
Series | Model | Input Voltage | Power capacity (kVA) | Input current | Output current (A) | Moter power(kW) |
A1 | S2 R4GB | Single-phase 200V~240V 50/60Hz |
1.0 | 5.1 | 2.3 | 0.4 |
S2R75GB | 1.7 | 9.2 | 4.0 | 0.75 | ||
S21R5GB | 2.8 | 13.1 | 7.0 | 1.5 | ||
S22R2GB | 4.0 | 23 | 9.6 | 2.2 | ||
3R75GB | Three-phase 380Vto480V 50/60Hz |
1.6 | 3.7 | 2.1 | 0.75 | |
31R5GB | 3.2 | 5.4 | 3.8 | 1.5 | ||
32R2GB | 4.8 | 7.0 | 5.1 | 2.2 | ||
3004GB | 6.0 | 10.7 | 9.0 | 4.0 |
Type | Terminal No | Name | Terminal Funciton | Specification |
Analog Input | AI1~AI2 | Analog inputs | Receive voltage/current input. Voltage or current are selected by DIP switch SW3 or SW1. Voltage input mode is the default mode. | Input voltage: 0~10V |
Input current: 0~20mA | ||||
Reference ground: GND | ||||
AO/AO1 | Analog output | Be able to output analog voltage/current. Voltage or current are selected by DIP switch SW2. | Output voltage: 0/2~10V | |
Output current: 0/4~20mA | ||||
Reference ground: GND | ||||
Analogy Output | AO2 | Analog output | Provide analog voltage/current output, with voltage and current selected by the DIP switch SW5. | Output voltage: 0/2~10V |
Output current: 0/4~20mA | ||||
Reference ground: GND |
Type | Terminal No | Name | Terminal Funciton | Specification |
Commu- nication | 485+ | RS485 interface | 485 differential signal positive terminal | Standard RS-485 communication interface, Not isolated to GND |
485- | 485 differential signal negative terminal | |||
Multi- Functional Input Terminal |
X1~X6 | Multi-function input terminals | It can be defined as a multi-function discrete input terminal through programming. | Optical-isolator input |
Input resistance: R=3.9kΩ | ||||
Input voltage: 0~30V | ||||
Reference ground: COM | ||||
Multi_x001f_Function Output | DO | Open collector output terminal | It can be defined as a multi-function output terminal for pulse signal through programming. It can also be used as an on-off output terminal. | Opto-coupler isolated OC output. |
operating voltage: 0V~26V | ||||
Maximum current: 50mA | ||||
Output frequency: 0~50kHz | ||||
Reference ground: COM | ||||
Electric Replay Output | TA | Relay output | It can be defined as a multi-function relay output terminal through programming. | TA-TB: NC TA-TC: NO Contact capacity: 250VAC/2A (COSΦ=1.0) 250VAC/1A (COSΦ=0.4) 30VDC/1A |
TB | ||||
TC | ||||
RA | Relay output | RA-RC: NO Contact Capacity: 250VAC/2A (COSΦ=1) 250VAC/1A(COSΦ=0.4) 30VDC/1A |
||
RC | ||||
PLC | Multifunctional input common terminal | When leaving the factory, it is shorted to 24V, and the PLC is internally isolated from 24V. Note: When using PLC, the SW4 jumper on the right side of the control terminal must be disconnected. |
X terminal supports NPN and PNP connection methods. | |
Power | 10V | +10V power supply | Provide +10V power supply externally (Reference ground: GND) |
Maximum output current 20 mA Open circuit voltage can be up to 12V |
24V | +24V power supply | Provide +24V power supply externally (Reference ground: COM) |
Maximum output current 100mA | |
GND | +10V Reference GND | Reference GND for analog signal and +10V power supply | Inner Isolated from COM COM for +10V, AI1, AI2, and AO1 |
|
COM | +24V Common GND | Used with other terminals | Isolated from GND | |
PE | Shield ground | It is used for grounding of terminal wiring shield layer. Shield layer of analog signal lines, 485 communication lines, and motor cables can be connected to this terminal | It is internally connected to connection terminal PE of main circuit. |
Subject | Specification |
Rated input voltage, frequency | 3 Phase 380V-440V, 50/60Hz |
Allowed input voltage working scope | 3 Phase 380V: 304V-456V, Voltage imbalance rate less than 3%, frequency less than +-5% |
Rated output voltage | 0~Rated input voltage |
Maximum overload current | Type G, 150%/min, 180%/20Sec. Type P, 120%/min, 150%/sec |
Control mode | VF/Current vector control |
Frequency controlling scope | Low frequency mode : 0.00-650.00Hz, High frequency mode: 0.0~1000Hz |
Frequency accuracy | Digital command: ±0.01 %(-10°C~ +40°C) Analog command: ±0.01 %(15°C~35°C) |
Set frequency resolution | Digital command: 0.01 Hz Analog command: 1/1000 maximum frequency |
Output frequency resolution | 0.01 Hz |
Frequency setting signal | 0~10V, 0~20mA |
Accelerating time | 0.1-3600 Seconds |
Braking torque | Additional braking torque up to 125% |
Voltage / Frequency features | 4 optional fixed VF features , and random VF feature setting with RG VF control |
Protection | Over-voltage, Under-voltage, Current Limit, Over-current, Overload, Electronic thermal relay , Over-heat, over-voltage with stall, short circuit load, touch ground, under-voltage protection, input default phase, output default phase, short circuit of touch ground or phases, motor overload protection, etc. |
Ambient temperature | -10°C~40°C |
Humidity | 5-95% RH |
Storage | Storage-40°C~70°C |
Working condition | Indoor without corrosive gas. |
Installation | Altitude not higher than 1000 Meters without dust, corrosive gas and sunlight direct radiation |
Vibration | Less than 5.9m/s2(0.6g) |
Protection level | lP20 |
Suppliers with verified business licenses